Saripalle, Sashi K.McLaughlin, AdamDerakhshani, RezaBrömme, ArslanBusch, ChristophDantcheva, AntitzaRaja, KiranRathgeb, ChristianUhl, Andreas2020-09-162020-09-162020978-3-88579-700-5https://dl.gi.de/handle/20.500.12116/34320This paper presents a comprehensive multispectral study of iris recognition on postmortem enucleated eyes over a period of three days. An off the shelf iris recognition methodology is employed to analyze the biometric capability of iris in the post mortem setting.We observed that iris patterns of enucleated eyes can provide biometric matches with no false accepts for up to 164 hours after death, albeit with high false rejection rates. We also present our observations on the effects of the environment and other confounding factors that may affect the performance of postmortem iris recognition, with recommendations for rehydration of specimen to regain postmortem biometric utility.enPostmortem biometricsiris recognitionbiometricsforensicsIris Recognition in Postmortem Enucleated EyesText/Conference Paper1617-5468